Difference between revisions of "Dispersion curve inversion"

From GeopsyWiki
Jump to navigation Jump to search
Line 18: Line 18:
 
Load a dispersion curve and fix its frequency sampling:
 
Load a dispersion curve and fix its frequency sampling:
  
* Load this [[Media:Test_Rayeigh_2modes.disp|dispersion curve]]. It is a theoretical curve computed using this [[Computing a theoretical dispersion curve|tutorial]].
+
* Load this . It is a theoretical curve computed using this [[Computing a theoretical dispersion curve|tutorial]].
 
* Select the fundamental curve  
 
* Select the fundamental curve  
 
::Use ''curve data scroll bar'' and ''visible button'' to identify it.
 
::Use ''curve data scroll bar'' and ''visible button'' to identify it.

Revision as of 12:24, 24 July 2009


This tutorial shows how to invert a dispersion curve measured for surface waves. It is based on dinverdc module used inside dinver framework.


Getting ready

Start Dinver with Surface Wave Inversion module.

At first glance, the interface might look a little bit messy. If it is the first time you start dinver, you'd better close all windows until having an empty workspace. The various tools will be displayed one by one and explained in this tutorial, in a logical order.

Importing the dispersion curve to fit

  • Activate the Target panel in menu Tools.
  • Select the Dispersion option. Leave the Misfit weigth and the Min. misfit to their default values, 1 and 0, respectively.
  • Click on Set to load the dispersion curve, the Dispersion curve target is displayed.

Load a dispersion curve and fix its frequency sampling:

  • Load this . It is a theoretical curve computed using this tutorial.
  • Select the fundamental curve
Use curve data scroll bar and visible button to identify it.
This is the curve defined over the complete frequency range and with higher slowness).
  • Re-sample it from 2 to 20 Hz on log scale with 50 samples (menu Actions/Resample).
  • Cut it from 2 to 20 Hz (menu Actions/Cut).
  • Select the first higher mode curve
Use curve data scroll bar and visible button to identify it.
This curve is not defined over the complete frequency range and it has a lower slowness).
  • Remove it (menu Actions/Remove).

Achieving a good frequency sampling is an art, for a better understanding see Curve sampling.

At this step, the Dispersion curve target should contain only one curve, the fundamental mode. Make sure the mode table contains only one item like this:

Dinverdc fundamental mode.png

Defining the parameter space

Running the inversion

Initialization log

Status

Viewing the results

Dispersions

Ground profiles

Parameter space projections

Command line queries