[[Image:HV_toolbox_time.png|thumb|right|200px|''General'' sub-tab in ''Time'' tab of the ''H/V toolbox'']] | [[Image:HV_toolbox_time.png|thumb|right|200px|''General'' sub-tab in ''Time'' tab of the ''H/V toolbox'']] | ||
* Make sure that the [[Geopsy: Toolbox_time_general|''H/V Toolbox'']] is showing the [[Geopsy: Toolbox_time_general|''Time tab'']], and that parameters are set as in the example window. | * Make sure that the [[Geopsy: Toolbox_time_general|''H/V Toolbox'']] is showing the [[Geopsy: Toolbox_time_general|''Time tab'']], and that parameters are set as in the example window. | ||
− | * To make sure that parameters are set up alright, it is possible to download the [[Media:Strong_peak.tgz|compressed parameter file]] and [[Geopsy: Load Parameters|load parameters]]. | + | * To make sure that parameters are set up alright, it is possible to download the [[Media:Strong_peak.tgz|compressed parameter file]] and [[Geopsy: Load Toolbox Parameters|load toolbox parameters]]. |
<br style="clear: both"/> | <br style="clear: both"/> | ||
Line 76: | Line 76: | ||
* It is possible to change the appearance of the H/V graphics at the user's will using a make-up. | * It is possible to change the appearance of the H/V graphics at the user's will using a make-up. | ||
* As an example, first download the [[HV_makeup.mkup.tgz|compressed make up file]]. | * As an example, first download the [[HV_makeup.mkup.tgz|compressed make up file]]. | ||
− | * Then right click in the | + | * Then right click in the left hand margin of the H/V graphics. |
− | * Select Restore make-up in the pop-up menu and then select HV_Makeup.mkup | + | * Select Restore make-up in the pop-up menu and then select HV_Makeup.mkup file. |
<br style="clear: both"/> | <br style="clear: both"/> | ||
[[Image:HV_toolbox_HV_mkup.png|thumb|right|200px|New H/V graphics appearance change after applying a make-up]] | [[Image:HV_toolbox_HV_mkup.png|thumb|right|200px|New H/V graphics appearance change after applying a make-up]] | ||
Line 87: | Line 87: | ||
[[Image:HV_toolbox_save_graph.png|thumb|right|200px|Pop-up menu to save H/V graphics]] | [[Image:HV_toolbox_save_graph.png|thumb|right|200px|Pop-up menu to save H/V graphics]] | ||
* The H/V graphics may be saved in various image formats. | * The H/V graphics may be saved in various image formats. | ||
− | * Right click in the | + | * Right click in the left hand margin of the H/V graphics. |
* In the pop-up menu choose ''Export image''. | * In the pop-up menu choose ''Export image''. | ||
<br style="clear: both"/> | <br style="clear: both"/> |
Revision as of 15:42, 9 March 2010
This tool is used to obtain Horizontal to Vertical (H/V) spectral ratios from any type of vibration signals (ambient vibrations, earthquake…). The example used for explanations is an ambient vibration recording.
The reference document for the H/V processing is the SESAME user guidelines, which is strongly recommended for further reading [1].
Contents
Getting ready
- Download compressed signal file.
- Load and view these downloaded signals.
- Select H/V in menu Tools (alternative ways to start a tool)
Window selection
- Make sure that the H/V Toolbox is showing the Time tab, and that parameters are set as in the example window.
- To make sure that parameters are set up alright, it is possible to download the compressed parameter file and load toolbox parameters.
- Click on the Raw signal sub-tab in Time tab, to check that the anti-trigger parameters are as in the example window.
- Click on the Select button and select Auto.
- The number of selected windows appears at the bottom right corner of the Time tab.
The number of windows should be as in the example.
- Selected windows should appear as green rectangles on the Signal viewer.
Processing parameters
- Click on the Processing tab, and make sure that parameters are as in the example window.
Output parameters
- Make sure you are in the Output tab, and that parameters are as in the example window.
Data processing
- If no window selection has been performed, a pup-up window appears.
Simply click on the Yes button and processing will follow its way.
Results
Signal diplay
- Selected windows are colored, matching colours in he H/V graphics, i.e. colour of individual H/V curves have the same colour as the signal windows.
H/V curve
- The blak curve represents H/V averaged over all colored individual H/V curves The two dashed lines represent H/V standard deviation.
- The grey area represent the peak frequency and its standard deviation. The frequency value is at the limit between the dark and clear areas.
* Use the cursor to get values on the H/V curve. The exact value of the H/V peak frequency and its standard deviation may be obtained by sliding the cursor onto the H/V curve title (Strong_peak) in the upper right corner above the graphics.
Changing H/V graphics appearance
- It is possible to change the appearance of the H/V graphics at the user's will using a make-up.
- As an example, first download the compressed make up file.
- Then right click in the left hand margin of the H/V graphics.
- Select Restore make-up in the pop-up menu and then select HV_Makeup.mkup file.
- The appearance of the H/V graphics is now at the user's taste.
Saving results
- The H/V graphics may be saved in various image formats.
- Right click in the left hand margin of the H/V graphics.
- In the pop-up menu choose Export image.