Geopsy: H/V and Spectrum Toolboxes: Time Tab
Contents
Use
This toolbox tab contains the parameters to select the part of the signal used for H/V or Spectrum processing on which window selection is performed. The two series of paramaters are described in two sections:
- the global time range section
- the time windows section
A third section gives information on the number of selected windows obtained after applying to the signal the parameters of the two precedent sections.
At the very bottom two buttons indicate wether to load parameters from previouly processed data or to start signal processing signal processing.
Global time range section
Used to select the portion of the signal that will be processed (more informations).
Time windows section
Short-duration disturbances of the signal can be avoided during H/V or Spectrum processing by using an anti-trigger window selection to remove the transients. The objective is to keep the most stationary parts of ambient vibrations, and to avoid the transients often associated with specific sources (footsteps, close traffic). This objective is exactly the opposite of the usual goal of seismologists who want to detect signals, and have developed specific trigger algorithm to track the unusual transients possibly indicating the satrt of an earthquake. Here an anti-trigger algorithm is used, which is exactly the opposite: it detects transients but it tries to avoid them. For more information on this topic it it suggested to consult the SESAME user guidelines [1]. Windows are then processed indidualy to get individual window H/V or Spectrum, which are then averaged.
This section comprises four sub-tabs:
- general: window selection parameters
- raw signal: STA/LTA crieria applied to the raw signal
- filter: filtering criteria for applying STA/LTA on the filtered signal
- filtered signal: STA/LTA crieria applied to the signal filtered uusing the criteria in the Filter sub-tab
General sub-tab
This sub-tab contains the criteria used to select stable signal windows.
Window length
There are three ways to define window length (duration, in seconds) using the Length pop-up menu
- Exactly: all selected windows will have the same exact duration.
Choose Exactly in the Length pop-up menu and enter the window length (in seconds) in the spin box to the right of the pop-up menu.
- At least: selected windows will have a duration comprised between two values.
Choose At least in the Length pop-up menu and enter the window lengths (in seconds) in the two spin boxes to the right of the pop-up menu.
All windows which duration is comprised between these two values will be selected, thus possibly resulting in windows with different sizes.
This may be useful so as to keep the most possible windows of very perturbated signal.
Window Overlaping
It is possible for succesive windows to be contiguous or to overlap, with the Overlap box and spin box.
- When the Overlap box is not checked, contiguous selected signal windows will not overlap.
- When the Overlap box is checked, contiguous selected signal windows will overlap by a chosen percentage entered in the neighboring spin box.
Bad Sample Definition and Use
The "bad sample" concept has been introduced for two purposes:
- eliminate clipped parts of recordings (which imply spectrum distorsions)
- introduce some "tolerance" on the sometimes too severe window selection criteria
A "bad sample" is therefore
- either a sample; with too high an amplitude (above a given threshold)
- or a sample which falls outside the specified STA/LTA range.
- Bad Sample Threshold box
This box allows to define the amplitude level above which a sample is considered as bad, and should be rejected when looking for usable windows.
To do so, check the Bad sample threshold box and enter the desired threshold in the spin box. The threshold is defined in terms of percentage of the maximum amplitude observed over the entire signal. (Thus, setting a 99% threshold will automatically eliminate all clipped parts of the recording)
- Bad Sample Tolerance box
A maximum number of bad samples may be accepted (tolerated) inside windows during the selection process. Check the Bad sample tolerance button, and enter the maximum cumulative time (in seconds) reached by all the bad sample that is accepted in selected windows.
Warning : It is recommended to use this option with care, and only whe the plain application of default values lead to a very small number of automatically selected windows.
Anti-triggering alternatives and criteria for window selection
The goal of the anti-triggering is to keep the most stationary parts of ambient vibrations, and to avoid the transients. User's defined "bad samples" - if any - are also considered as to be avoided.
Two types of anti-triggers may be applied to he signal, both based on STA/LTA detection.
- Anti-triggering on raw signal
When the Anti-triggering on raw signal box is checked, the anti-trigger is applied sample per sample all along the entire signal, using the STA/LTA parameters entered in the Raw signal sub-tab.
- Anti-triggering on filtered signal
When the Anti-triggering on filtered signal box is checked, the signal is first filtered using the parameters entered in the Filter sub-tab, and then the anti-trigger is applied sample per sample all along the entire signal, using the STA/LTA parameters entered in the Filtered signal sub-tab.
All box checking combinations are possible, including both boxes unchecked or checked. In the latter case only samples that fullfill the criteria of both antitriggers are considered as part of a "quadi-stationary" signal. When none are checked no anti-trigger is apllied in the window selection.
It is thus possible to select windows based only on the Bad Sample criteria, or even no criteria.
IMPORTANT NOTICE: when using the anti-triggering on the filtered signal, the signal is filtered ONLY for the window selection process. The later processing (FFT, H/v etc...) is then performed on the original RAW signal. In order to process filtered signal the raw signal should first be filtered with the Filter in the Waveform menu.
Raw Signal sub-tab
This sub-tab is divided into two sections.
- STA/LTA parameters section (to the left), includes STA length, LTA length, as well as minimum and maximum STA/LTA thresholds (more information).
- Apply to section (to the right), indicates to which tracks and which files the anti-trigger is applied .
H/V display
The tracks are displayed at the top of the section, and the files below the "..."
Spectrum display
Simply check the boxes of the tracks and files that are to be processed.
Filter sub-tab
Contains the filtering parameters used in the Filtered Signal sub-tab (more details).
Filtered Signal sub-tab
This sub-tab is divided into two sections.
- STA/LTA parameters section (to the left), includes STA length, LTA length, as well as minimum and maximum STA/LTA thresholds (more information).
- Apply to section (to the right), indicates to which tracks the anti-trigger is applied (top, above the … : Vertical, North, East) and to which file (bottom underneath the … : "Strong Peak").
Simply check the boxes of the tracks and files that are to be processed.
Windowing and data flow sub-section
Two boxes and one pop-up menu located at the bottom of the Time windows section are used to control windowing and real time data acquistion flow.
- Update box: should be checked when using geopsy for real time data acquisition. Checking the box when no data flow is entering as no effect on the processing.
- Common box: check this box to force selecting the same windows on all signal tracks, i.e. STA/LTA threshold must be verified simultaneously on all tracks in order to keep a window. When the box is unchecked, STA/LTA threshold must be verified on each track taken separately. There is no need to check this box in H/V processing, as in this case it is automatically applied.
- Select pop-up menu: used to determine which action is undertaken in the windowing process.
When the windowing has not yet been performed with the current parameters, a "*" is displayed besides Select (Select*).
Auto: windows are selected automaticaly using the criteria of the General sub-tab of the Time section.
Add: manualy add windows. Choose this option and then, with the cursor, select a zone in the signal display where windows have to be added. If an existing window is included in the zone it will not be affected.
Remove: manualy remove windows. Choose this option and then, with the cursor, select a zone in the signal display where windows have to the removed.
Inverse: select the windows that were previously not selected. When no windowing has been performed, applying Inverse will select windows all along the signal without applying the windowing criteria.
Clear: automatically remove all windows.
Load: load windows from previous processing stored in a name.log file.
Number of windows section
In the Number of windows section, underneath the Toolbox tabs, a pop-up menu and a numerical display are used to show the number of selected windows.
When "all stations" is displayed in the pop-up menu, the number of windows in the numerical display is the total number of windows selected over the entire station set. It is also displayed when a single station is processed.
The number of windows selected in each station of a multiple processing may be displayed using the pop-up menu.
The number of windows of the selected station appears in the numerical display.
Load parameters and Start section
The section at the bottom of the Time tab comprises two buttons.
- The Load parameters button is used to load parameters from previous H/V or spectrum processing stored in a name.log file (example).
- Press the Start button to start H/V or Spectrum processing.
If no window selection has been performed, a pup-up window appears.
Simply click on the Yes button and processing will follow its way with the current Toolbox parameters.
To perform user's windowing, click on the No button.