Difference between revisions of "Geopsy: H/V and Spectrum Toolboxes"

From GeopsyWiki
Jump to navigation Jump to search
 
(44 intermediate revisions by 5 users not shown)
Line 1: Line 1:
== Use ==
+
'''These toolboxes, besides some exceptions noted in the text, are common to the following tools:'''
The H/V and Spectrum toolboxes contains all the parameters needed for windowing, processing, grapics appearance,
+
* '''H/V spectral ratio'''
and output destination. It also contains some informations about processing results.
+
* '''Spectrum'''
 +
* '''H/V rotate'''
 +
* '''Spectrum rotate'''
  
It comprises three tabs, divided in two to three areas grouping the same type of parameters. One
 
area comprises four sub-tabs.
 
  
Do not forget that each change made in a toolbox is preserved for the next use of this toolbox.
+
= Use =
It is strongly recommended to verify the parameters in the toolbox before running the windowing or the H/V-Spectrum computation.
+
These toolboxes contain all the parameters needed for windowing, processing, graphics appearance,
 +
and output destination. They also contain some information about processing results.
  
== [[Geopsy: H/V and Spectum Toolboxes: Time Tab|Time Tab]] ==
+
It comprises three tabs (Time, Processing and Output), divided in two to three sections grouping parameters of the same type.  
[[Image:HV_SPEC_toolb_time.png|50px]]
+
Here below, the tabs inside a section are termed sub-tabs .
* Global time range area: selection of a portion of the signal [[Image:HV_SPEC_toolb_time_global.png|50px]]
 
* Time windows area [[Image:HV_SPEC_toolb_time_time.png|50px]]
 
** General sub-tab: windowing parameters [[Image:HV_SPEC_toolb_time_time_gen.png|50px]]
 
** Raw signal sub-tab: anti-triggering parameters for raw signal [[Image:HV_SPEC_toolb_time_time_raw.png|50px]]
 
** Filter sub-tab: filter parameters for filetered signal anti-triggering [[Image:HV_SPEC_toolb_time_time_filter.png|50px]]
 
** Filtered signal sub-tab: anti-triggering parameters for filtered signal [[Image:HV_SPEC_toolb_time_time_filtered.png|50px]]
 
* Windows area: number of windows [[Image:HV_SPEC_toolb_time_nbwindows.png|50px]]
 
  
  
== [[Geopsy: H/V and Spectum Toolboxes: Processing Tab|Processing tab]] ==
+
* '''Note: changes made in a toolbox are preserved for its next use when closing the signal window or when quitting Geopsy. '''<br/>'''It is however strongly recommended to verify the parameters in the toolbox before running the windowing or the H/V-Spectrum computation.'''
[[Image:HV_SPEC_toolb_process.png|50px]]
 
* Parameters area: processing parameters [[Image:HV_SPEC_toolb_process_param.png|50px]]
 
* Horizontal components area (optional): the way to deal with horizontal components[[Image:HV_SPEC_toolb_process_horizontal.png|50px]]
 
  
  
== [[Geopsy: H/V and Spectum Toolboxes: Output Tab|Output tab]] ==
+
= Time Tab =
[[Image:HV_SPEC_toolb_output.png|50px]]
+
[[Image:HV_SPEC_toolb_time.png|thumb|right|300px|Time Tab]]
* Frequency sampling area: parameters on frequency [[Image:HV_SPEC_toolb_output_frequency.png|50px]]
+
* [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Global time range section|Global time range]] section: selection of a portion of the signal
* Appearance area: automatic output graphics appearance parameters [[Image:HV_SPEC_toolb_output_appearance.png|50px]]
+
* [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Time windows section|Time windows]] section:
* Output area: where to save data [[Image:HV_SPEC_toolb_output_output.png|50px]]
+
** [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Time windows section#General sub-tab|General]] sub-tab: windowing parameters
 +
** [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Time windows section#Raw signal sub-tab|Raw signal]] sub-tab: anti-triggering parameters for raw signal
 +
** [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Time windows section#Filter sub-tab|Filter]] sub-tab: filter parameters for filetered signal anti-triggering
 +
** [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Time windows section#Filtered signal sub-tab|Filtered signal]] sub-tab: anti-triggering parameters for filtered signal
 +
* [[Geopsy: H/V and Spectum Toolboxes: Time Tab#Number of windows section|Number of windows]] section
  
  
== [[Geopsy: Load_Toolbox_Parameters|Load parameters and start processing]] ==
+
 
To load windowing and processing parameters from previous processings, or start processing [[Image:HV_SPEC_toolb_load_start.png|50px]]
+
'''Main article''': [[Geopsy: H/V and Spectum Toolboxes: Time Tab|Time Tab]]
 +
 
 +
<br style="clear: both"/>
 +
 
 +
= Processing Tab =
 +
[[Image:HV_SPEC_toolb_process.png|thumb|right|300px|Processing Tab]]
 +
* [[Geopsy: H/V and Spectum Toolboxes: Processing Tab#Parameters section|Parameters section]]: processing parameters  
 +
* [[Geopsy: H/V and Spectum Toolboxes: Processing Tab#Horizontal components section (only available for HV toolbox) |Horizontal components section]] (for H/V spectral ratio only): the way to deal with horizontal components
 +
 
 +
 
 +
 
 +
'''Main article''':  [[Geopsy: H/V and Spectum Toolboxes: Processing Tab|Processing tab]]  
 +
 
 +
<br style="clear: both"/>
 +
 
 +
= Output Tab =
 +
[[Image:HV_SPEC_toolb_output.png|thumb|300px|Output tab]]
 +
* [[Geopsy: H/V and Spectum Toolboxes: Output Tab#Frequency sampling section|Frequency sampling]] section: parameters on frequency
 +
* [[Geopsy: H/V and Spectum Toolboxes: Output Tab#Appearance section|Appearance]] section: automatic output graphics appearance parameters
 +
* [[Geopsy: H/V and Spectum Toolboxes: Output Tab#Output section| Output]] section: where to save the results
 +
 
 +
 
 +
 
 +
'''Main article''':  [[Geopsy: H/V and Spectum Toolboxes: Output Tab|Output tab]]
 +
 
 +
<br style="clear: both"/>
 +
 
 +
= Load parameters and start processing =
 +
[[Image: HV_SPEC_toolb_load_start.png|thumb|right|300px|Load parameters and Start section]]Two buttons are displayed at the bottom of the '''Time''' tab:
 +
 
 +
*'''Load parameters''': to load Toolbox parameters from previous processing
 +
*'''Start''': to start processing the data
 +
 
 +
 
 +
 
 +
'''Main article''': [[Geopsy: Load_Toolbox_Parameters|Load parameters and start processing]]
 +
<br style="clear: both"/>

Latest revision as of 16:27, 27 February 2013

These toolboxes, besides some exceptions noted in the text, are common to the following tools:

  • H/V spectral ratio
  • Spectrum
  • H/V rotate
  • Spectrum rotate


Use

These toolboxes contain all the parameters needed for windowing, processing, graphics appearance, and output destination. They also contain some information about processing results.

It comprises three tabs (Time, Processing and Output), divided in two to three sections grouping parameters of the same type. Here below, the tabs inside a section are termed sub-tabs .


  • Note: changes made in a toolbox are preserved for its next use when closing the signal window or when quitting Geopsy.
    It is however strongly recommended to verify the parameters in the toolbox before running the windowing or the H/V-Spectrum computation.


Time Tab

Time Tab


Main article: Time Tab


Processing Tab

Processing Tab


Main article: Processing tab


Output Tab

Output tab


Main article: Output tab


Load parameters and start processing

Load parameters and Start section

Two buttons are displayed at the bottom of the Time tab:

  • Load parameters: to load Toolbox parameters from previous processing
  • Start: to start processing the data


Main article: Load parameters and start processing