Difference between revisions of "Smoothing details"

From GeopsyWiki
Jump to navigation Jump to search
(New page: The Konno and Ohmachi (1999) smoothing id defined by the following function: 100px, where: *f is the frequency *fc is the central frequency *b is the...)
 
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
−
The Konno and Ohmachi (1999) smoothing id defined by the following function: [[Image:Konno_Ohmachi_formula.png|100px]], where:
+
The Konno and Ohmachi (1998) <ref name="Konno and Ohmachi (1998)">Konno, K. and Omachi, T., 1998, Bull. Seism. Soc. Am., 88, 228-241.</ref> smoothing is defined by the following function: <!--[[Image:Konno_Ohmachi_formula.png|100px]]-->
 +
<math>\left(\frac{\sin(b\log_{10}(\frac{f}{f_c})}{b\log_{10}(\frac{f}{f_c})}\right)^4</math>, where:
  
−
*f is the frequency
+
* <math>f</math> is the frequency
  
−
*fc is the central frequency
+
* <math>f_c</math> is the central frequency
  
−
*b is the bandwidth coefficient.
+
* <math>b</math> is the bandwidth coefficient.
  
−
As the Konno and Ohmachi smoothing function preserves the different number of points at low and high frequency, it use is strongly recommended for works on frequency analysis.
+
Konno and Ohmachi smoothing function is strongly recommended for frequency analysis because it ensures a constant number points at low and high frequency.
  
 +
[[Image:Konno_Ohmachi_vs_triangle_smoothing.png|thumb|center|300px|Comparison between ''Konno and Ohmachi'' and triangular window smoothing.]]
  
−
[[Image:Konno_Ohmachi_vs_triangle_smoothing.png|thumb|center|300px|this smoothing is recommanded because this function preserves the different number of points at low and high frequency]]
+
== References ==
 +
<references/>

Latest revision as of 16:22, 14 April 2012

The Konno and Ohmachi (1998) [1] smoothing is defined by the following function: , where:

  • is the frequency
  • is the central frequency
  • is the bandwidth coefficient.

Konno and Ohmachi smoothing function is strongly recommended for frequency analysis because it ensures a constant number points at low and high frequency.

Comparison between Konno and Ohmachi and triangular window smoothing.

References

  1. ↑ Konno, K. and Omachi, T., 1998, Bull. Seism. Soc. Am., 88, 228-241.