Difference between revisions of "Geopsy: Load Toolbox Parameters"
Jump to navigation
Jump to search
(New page: * It is possible to load H/V and Spectrum windowing and processing parameters from previous processings, which were set up in the corresponding Toolbox * H/V parameter...) |
|||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | + | [[Image: HV_SPEC_toolb_load_start.png|thumb|right|300px|Load parameters and Start section]] | |
+ | Two options are displayed at the bottom of each tab of the H/V, Spectrum, FK, HRFK and MSPAC toolboxes. | ||
+ | <br style="clear: both"/> | ||
+ | |||
+ | |||
− | + | = Load parameters = | |
+ | It is possible to load windowing and processing parameters from previous processings, which were set up in the corresponding toolboxes (HV, Spectrum, FK, HRFK, MSPAC ...). | ||
− | * | + | * H/V parameters are stored in a '''name.log''' file ([[Geopsy: H/V_parameter_file|Example]]), where 'name' stands for the station name |
− | * Click on the ''Start'' button at the bottom of the toolbox, whatever tab is displayed | + | * Spectrum parameters are stored in '''name_Z.log''', ''name_E.log''', and '''name_N.log''' files ([[Geopsy: Spectrum_parameter_file|Example]]), where 'name' stands for the station name |
+ | |||
+ | * SPAC parameters are stored in a '''basename.log''' file ([[Geopsy: SPAC_parameter_file|Example]]), where 'basename' stands for the output file name requested for the processing. | ||
+ | |||
+ | * FK, HRFK parameters are stored in a '''basename.log''' file ([[Geopsy: FK_parameter_file|Example]]), where 'basename' stands for the output file name requested for the processing. | ||
+ | |||
+ | |||
+ | |||
+ | = Start processing = | ||
+ | |||
+ | Click on the '''Start''' button at the bottom of the toolbox, whatever tab is displayed: processing will follow its way with the current [[Geopsy: H/V and Spectrum Toolboxes| Toolbox]] parameters. | ||
<br style="clear: both"/> | <br style="clear: both"/> | ||
+ | |||
+ | |||
+ | |||
+ | [[Image:HV_toolbox_no_window_selected.png|thumb|right|300px|Pop-up window indicating that no window selection has been performed]] | ||
+ | If no window selection has been performed when starting to process data, a pup-up window appears. | ||
+ | |||
+ | To proceed with current parameters click on the '''Yes''' button. | ||
+ | To change the windowing parameters click on the '''No''' button. |
Latest revision as of 14:20, 27 February 2013
Two options are displayed at the bottom of each tab of the H/V, Spectrum, FK, HRFK and MSPAC toolboxes.
Load parameters
It is possible to load windowing and processing parameters from previous processings, which were set up in the corresponding toolboxes (HV, Spectrum, FK, HRFK, MSPAC ...).
- H/V parameters are stored in a name.log file (Example), where 'name' stands for the station name
- Spectrum parameters are stored in name_Z.log', name_E.log, and name_N.log files (Example), where 'name' stands for the station name
- SPAC parameters are stored in a basename.log file (Example), where 'basename' stands for the output file name requested for the processing.
- FK, HRFK parameters are stored in a basename.log file (Example), where 'basename' stands for the output file name requested for the processing.
Start processing
Click on the Start button at the bottom of the toolbox, whatever tab is displayed: processing will follow its way with the current Toolbox parameters.
If no window selection has been performed when starting to process data, a pup-up window appears.
To proceed with current parameters click on the Yes button. To change the windowing parameters click on the No button.