Difference between revisions of "Geopsy: H/V and Spectrum Toolboxes: Time Tab"
Line 1: | Line 1: | ||
= '''Use''' = | = '''Use''' = | ||
− | + | [[Image:HV_SPEC_toolb_time.png|thumb|right|300px|''Time'' tab of the H/V and Spectrum toolboxes]] | |
− | + | The '''Time tab''' of the '''H/V and Spectrum toolboxes''' is used to customize the parameters for selecting the signal windows which are used for [[H/V_spectral_ratio|H/V]] or [[Spectral_amplitudes|Spectrum]] processing. | |
+ | Two series of parameters are described in two sections: | ||
* the global time range section | * the global time range section | ||
Line 9: | Line 10: | ||
A third section gives information on the number of selected windows obtained after applying to the signal the parameters of the two precedent sections. | A third section gives information on the number of selected windows obtained after applying to the signal the parameters of the two precedent sections. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
<br style="clear: both"/> | <br style="clear: both"/> | ||
Line 55: | Line 51: | ||
− | == Raw | + | == Raw signal sub-tab == |
− | [[Image: HV_SPEC_toolb_time_time_raw.png|thumb|right| | + | [[Image: HV_SPEC_toolb_time_time_raw.png|thumb|right|300px]] |
This sub-tab is divided into two sections: | This sub-tab is divided into two sections: | ||
* '''STA/LTA parameters section''' (to the left) | * '''STA/LTA parameters section''' (to the left) | ||
Line 62: | Line 58: | ||
− | A box at the bottom indicates whether or not the anti-trigger is | + | A box at the bottom indicates whether or not the anti-trigger is applied to the raw signal. |
− | '''MAIN ARTICLE''': [[Geopsy: H/V and Spectrum Toolboxes: Time Tab: | + | '''MAIN ARTICLE''': [[Geopsy: H/V and Spectrum Toolboxes: Time Tab: Anti-trigger parameters|Anti-trigger parameters]] |
<br style="clear: both"/> | <br style="clear: both"/> | ||
Line 73: | Line 69: | ||
[[Image: HV_SPEC_toolb_time_time_filter.png|thumb|right|300px]] | [[Image: HV_SPEC_toolb_time_time_filter.png|thumb|right|300px]] | ||
− | Contains the filtering parameters | + | Contains the filtering parameters [[Geopsy: Filter|''(more details)'']] used in the ''Filtered Signal'' sub-tab. |
<br style="clear: both"/> | <br style="clear: both"/> | ||
− | == Filtered | + | == Filtered signal sub-tab == |
[[Image: HV_SPEC_toolb_time_time_filtered.png|thumb|right|300px]] | [[Image: HV_SPEC_toolb_time_time_filtered.png|thumb|right|300px]] | ||
− | |||
+ | This sub-tab is divided into two sections: | ||
+ | * '''STA/LTA parameters section''' (to the left) | ||
+ | * '''Apply to section''' (to the right) | ||
− | |||
− | + | A box at the bottom indicates whether or not the anti-trigger is applied to the filtered signal. | |
− | + | ||
+ | |||
+ | |||
+ | '''MAIN ARTICLE''': [[Geopsy: H/V and Spectrum Toolboxes: Time Tab: Anti-trigger parameters|Anti-trigger parameters]] | ||
+ | <br style="clear: both"/> | ||
+ | |||
Line 137: | Line 139: | ||
<br style="clear: both"/> | <br style="clear: both"/> | ||
− | = Number of windows section = | + | = '''Number of windows section''' = |
In the ''Number of windows'' section, underneath the [[Geopsy: H/V and Spectrum Toolboxes|''Toolbox'']] tabs, a pop-up menu and a numerical display are used to show the number of selected windows. | In the ''Number of windows'' section, underneath the [[Geopsy: H/V and Spectrum Toolboxes|''Toolbox'']] tabs, a pop-up menu and a numerical display are used to show the number of selected windows. | ||
Revision as of 17:47, 25 February 2013
Contents
Use
The Time tab of the H/V and Spectrum toolboxes is used to customize the parameters for selecting the signal windows which are used for H/V or Spectrum processing. Two series of parameters are described in two sections:
- the global time range section
- the time windows section
A third section gives information on the number of selected windows obtained after applying to the signal the parameters of the two precedent sections.
Global time range section
Used to select the portion of the signal that will be processed (more informations).
Time windows section
Short-duration disturbances of the signal can be avoided during H/V or Spectrum processing by using an anti-trigger window selection to remove the transients. The objective is to keep the most stationary parts of ambient vibrations, and to avoid the transients often associated with specific sources (footsteps, close traffic). This objective is exactly the opposite of the usual goal of seismologists who want to detect signals, and have developed specific trigger algorithm to track the unusual transients possibly indicating the start of an earthquake. Here an anti-trigger algorithm is used, which is exactly the opposite: it detects transients and tries to avoid them. For more information on this topic, it it suggested to consult the SESAME user guidelines [1]. Windows are then processed individually to get H/V or Spectrum curves in all selected windows, which are then averaged.
This section comprises four sub-tabs:
- General: window selection parameters
- Raw signal: STA/LTA crieria applied to the raw signal
- Filter: filtering criteria for applying STA/LTA on the filtered signal
- Filtered signal: STA/LTA criteria applied to the filtered signal using the filtering criteria in the Filter sub-tab
General sub-tab
This sub-tab contains the criteria used to select stable signal windows:
- Window length
- Window overlap
- Bad sample set-up
- Anti-triggering set-up
MAIN ARTICLE: General sub-tab
Raw signal sub-tab
This sub-tab is divided into two sections:
- STA/LTA parameters section (to the left)
- Apply to section (to the right)
A box at the bottom indicates whether or not the anti-trigger is applied to the raw signal.
MAIN ARTICLE: Anti-trigger parameters
Filter sub-tab
Contains the filtering parameters (more details) used in the Filtered Signal sub-tab.
Filtered signal sub-tab
This sub-tab is divided into two sections:
- STA/LTA parameters section (to the left)
- Apply to section (to the right)
A box at the bottom indicates whether or not the anti-trigger is applied to the filtered signal.
MAIN ARTICLE: Anti-trigger parameters
Windowing and data flow sub-section
Two boxes and one pop-up menu located at the bottom of the Time windows section are used to control windowing and real time data acquisition flow.
- Update box: should be checked when using geopsy for real time data acquisition. Checking the box when no data flow is entering has no effect on the processing.
- Common box: check this box to force selecting the same windows on all signal tracks, i.e. STA/LTA threshold must be verified simultaneously on all tracks in order to keep a window. When the box is unchecked, STA/LTA threshold must be verified on each track taken separately. There is no need to check this box in H/V processing, as in this case it is automatically applied.
- Select pop-up menu: used to determine which action is undertaken in the windowing process.
When the windowing has not yet been performed with the current parameters, a "*" is displayed besides Select
When the windowing has already been performed with the current parameters, the "*" is no longer displayed besides Select
The window selection process includes five possible actions.
Auto: windows are selected automatically using the criteria of the General sub-tab of the Time section.
Add: manually add windows. Choose this option and then, with the cursor, select a zone in the signal display where windows have to be added. If an existing window is included in the zone it will not be affected. Note that a window is added only if the criteria of the General sub-tab of the Time section are fulfilled.
Remove: manually remove windows. Choose this option and then, with the cursor, select a zone in the signal display where windows have to the removed.
Inverse: select the windows that were previously not selected. When no windowing has been performed, applying Inverse will select windows all along the signal without applying the windowing criteria.
Clear: automatically remove all windows.
Load: load windows from previous processing stored in a name.log file.
Number of windows section
In the Number of windows section, underneath the Toolbox tabs, a pop-up menu and a numerical display are used to show the number of selected windows.
When "all stations" is displayed in the pop-up menu, the number of windows in the numerical display is the total number of windows selected over the entire station set. It is also displayed when a single station is processed.
The number of windows selected in each station of a multiple processing may be displayed using the pop-up menu.
The number of windows of the selected station appears in the numerical display, and simultaneously the graphic display zooms on the selected station.
Load parameters and Start section
The section at the bottom of the Time tab comprises two buttons.
- The Load parameters button is used to load parameters from previous H/V or spectrum processing stored in a name.log file (example).
- Press the Start button to start H/V or Spectrum processing.
If no window selection has been performed, a pup-up window appears.
Simply click on the Yes button and processing will follow its way with the current Toolbox parameters.
To perform user's windowing, click on the No button.