Difference between revisions of "Geopsy: Spectrum parameter file"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | * Parameters stored in this type of file are the parameters used in the ''Spectrum'' [[Geopsy: | + | * Parameters stored in this type of file are the parameters used in the ''Spectrum'' [[Geopsy: H/V and Spectrum Toolboxes|Toolbox]] |
− | * Windowing log (length, duration…) also stored in .log files are not used when loading [[Geopsy: | + | * Windowing log (length, duration…) also stored in .log files are not used when loading [[Geopsy: H/V and Spectrum Toolboxes|Toolbox]] parameters |
* Only the lines in between ### Parameters ### and ### End Parameters ### are used when loading parameters | * Only the lines in between ### Parameters ### and ### End Parameters ### are used when loading parameters | ||
− | * Lines starting with # are ignored when loading the file in the [[Geopsy: | + | * Lines starting with # are ignored when loading the file in the [[Geopsy: H/V and Spectrum Toolboxes|Toolbox]] |
### Parameters ### | ### Parameters ### |
Latest revision as of 13:47, 12 March 2010
- Parameters stored in this type of file are the parameters used in the Spectrum Toolbox
- Windowing log (length, duration…) also stored in .log files are not used when loading Toolbox parameters
- Only the lines in between ### Parameters ### and ### End Parameters ### are used when loading parameters
- Lines starting with # are ignored when loading the file in the Toolbox
### Parameters ### SIGNAL FILE NAME = Strong_peak WINDOW MIN LENGTH (s) = 25 WINDOW MAX LENGTH (s) = 50 WINDOW LENGTH TYPE (at least/exactly/freq. dep.) = exactly DO BAD SAMPLE TOLERANCE (y/n) = n BAD SAMPLE TOLERANCE (s) = 0 DO WINDOW OVERLAP (y/n) = n WINDOW OVERLAP (%) = 5 DO BAD SAMPLE THRESHOLD (y/n) = n BAD SAMPLE THRESHOLD (%) = 99 ANTI-TRIGGERING ON RAW SIGNAL (y/n) = y USED RAW COMPONENTS = y, n, y, y, y RAW STA (s) = 1 RAW LTA (s) = 30 RAW MIN SLTA = 0.2 RAW MAX SLTA = 2.5 ANTI-TRIGGERING ON FILTERED SIGNAL (y/n) = n FILTER TYPE (low pass/high pass/band pass/band reject) = low pass FILTER METHOD (butterworth/taper) = taper FILTER MIN FREQUENCY (Hz) = 5 FILTER MAX FREQUENCY (Hz) = 10 FILTER CAUSAL (y/n) = n FILTER ORDER = 1 FILTER WIDTH = 0.1 USED FILTERED COMPONENTS = y, n, y, y, y FILTERED STA (s) = 1 FILTERED LTA (s) = 30 FILTERED MIN SLTA = 0.2 FILTERED MAX SLTA = 2.5 SMOOTHING TYPE (konno & ohmachi/constant band/proportional/no smoothing) = konno & ohmachi SMOOTHING CONSTANT = 40,00 DO COSINE TAPER = true TAPER WIDTH = 5 DO HIGH PASS = false HIGH PASS FREQUENCY = 1 MINIMUM FREQUENCY = 0.5 MAXIMUM FREQUENCY = 20 INVERSED FREQUENCY = n SAMPLES NUMBER FREQUENCY = 1000 SAMPLING TYPE FREQUENCY (0=log, 1=linear)= 0 ### End Parameters ### ### Windowing Log ### Common Automatic windowing Adding window from 59274.3 to 59299.3 s. Adding window from 59311.7 to 59336.7 s. Adding window from 59358.9 to 59383.9 s. Adding window from 59428.8 to 59453.8 s. Adding window from 59453.8 to 59478.8 s. Adding window from 59478.8 to 59503.8 s. Adding window from 59503.8 to 59528.8 s. Adding window from 59528.8 to 59553.8 s. Adding window from 59553.8 to 59578.8 s. Adding window from 59624.5 to 59649.5 s. Adding window from 59665.9 to 59690.9 s. Adding window from 59714.4 to 59739.4 s. Adding window from 59739.4 to 59764.4 s. Adding window from 59786.3 to 59811.3 s. Adding window from 59811.3 to 59836.3 s. Adding window from 59863.6 to 59888.6 s. ### End Windowing Log ### ### Time Windows ### # Number= 16 # Start time End Time Window length 59274.3 59299.3 25 59311.7 59336.7 25 59358.9 59383.9 25 59428.8 59453.8 25 59453.8 59478.8 25 59478.8 59503.8 25 59503.8 59528.8 25 59528.8 59553.8 25 59553.8 59578.8 25 59624.5 59649.5 25 59665.9 59690.9 25 59714.4 59739.4 25 59739.4 59764.4 25 59786.3 59811.3 25 59811.3 59836.3 25 59863.6 59888.6 25 ### End Time Windows ###